| Manufacturer |
Promise Technology, Inc. |
| Model number |
FastTrak100 |
| Controller type |
Bus master Ultra ATA/100
RAID controller |
| Board controller type |
PCI |
| Included cabling |
Two (2) 80-wire/40-pin drive cables |
|
|
|
| RAID
Levels supported |
0 (Striping), 1 (Mirroring) |
| Maximum # of arrays per card |
2 |
| RAID 0 drive
support |
From 1 to 4 drives
(Dell recommends creating 2-drive RAID 0 arrays only) |
| RAID 1 drive
support |
2 drives only
|
| # of drive channels |
2 (supports up to 4 drives) |
| FastBuild Configuration
Utility |
Can automatically create
RAID arrays from attached drives; identifies drives assigned to array;
delete and rebuild arrays |
| FastCheck Monitoring Utility |
GUI supports Windows interface for local monitoring
of FastTrak arrays; perform array maintenance; create system event logs
for administration |
|
|
|
| Types supported |
Ultra ATA/100, Ultra ATA/66, Ultra ATA/33,
EIDE, Fast ATA-2 |
| Maximum # of
drives supported |
4 (2 drives per
cable) |
| Drive modes |
Ultra DMA 5/4/3/2, PIO 4/3/2,
DMA 2/1/0 |
| Data transfer rate |
100MB/sec burst transfers
with Ultra ATA/100 drives |
| # of drive channels |
2 (supports up to 4 drives) |
| Device timing |
Independent timing for each drive/device attached
to cable |
|
|
|
| Bus support |
PCI local bus spec 2.1 and
higher |
| Bus speed |
33MHz |
| Maximum data transfer rate across bus |
133MHz |
| Bus mastering |
32-bit PCI bus mastering
with 0-wait state |
| DMA operation |
Hardware scatter/gather
for efficient command processing |
| Interrupt request
(IRQ) requirement |
Uses one shareable IRQ for
both data channels |
|
|
|
| Drive capacity |
Extended Int32 support recognizes drives up
to and larger than 8.4GB each up to 128GB |
| Device recognition |
Automatically identifies & configures drive
type (EIDE or Ultra DMA mode) without system CMOS setup |
| Ultra DMA support |
Automatically supports Ultra DMA mode data
transfers |
| Error checking |
Supports Cyclical Redundancy Checking (CRC)
of Ultra ATA drives |
| Data transfer modes |
Supports LBA (Logical Block Address) or normal
CHS data transfer modes |
| Bootability |
Allows booting from all FastTrak arrays |
| Upgradeability |
Supports Flash BIOS functions |
|
|
|
| Compatibility |
Windows NT 4.0/Windows 2000/Windows
98 |
|
|
|
| Height |
66.7 mm (2.625 inches) |
| Width |
120.7 mm (4.75 inches) |
|
|
|
| Operating temperature
(optimum) |
0 to 50 °C (32 to 122 °F) |
| Relative humidity |
5% -95% non-condensing |
| Voltage |
5V±5% |