Overview

The Dell PowerEdge 2400 workgroup server is a high performance system that offers strong availability, serviceability, and manageability features. The PowerEdge 2400 server utilizes Intel® Pentium® III microprocessors and next-generation chipset and memory technology to provide high performance in both file/print and server application environments.

This section describes the hardware features that simplify servicing of PowerEdge 2400 systems. It also describes major hardware and software features of the computer system.


Service Features

The PowerEdge 2400 systems include the following service features to make troubleshooting and repair easy and effective:

  • Dell Diagnostics, which checks for hardware problems (if the system can boot).

  • Embedded server management hardware, which monitors temperatures and voltages throughout the system and notifies you if the system overheats, if a system cooling fan malfunctions, or if a power supply fails.

  • Optional redundant, hot-pluggable power supplies.

The PowerEdge 2400 system chassis simplifies removing and replacing computer components. You can perform replacement of microprocessors or DIMMs without removing the system board. The Dell-designed SCSI backplane board and hard-disk drive carriers eliminate the extensive cabling and drive configuration usually required for a SCSI subsystem.


System Features

The PowerEdge 2400 systems offer the following major features:

  • One or two Pentium III microprocessors with an internal operating frequency of at least 500 MHz and an external bus speed of 100 or 133 MHz.

    The Pentium III microprocessor includes MMX™ technology designed to handle complex multimedia and communications software. This microprocessor incorporates new instructions and data types as well as a technique called single instruction, multiple data (SIMD) that allows the microprocessor to process multiple data elements in parallel, thereby improving overall system performance.

    A secondary level 2 (L2) cache of 256 KB or 512 KB of SRAM is included within the single-edge contact (SEC) cartridge that contains the microprocessor. Secondary L2 cache is 512 KB only in the 100 MHz FSB processors. Math coprocessor functions are provided by the microprocessor. A separate and external math coprocessor chip is not used or required.
  • Support for symmetric multiprocessing (SMP) is available by installing a second Pentium III microprocessor. SMP greatly improves overall system performance by dividing microprocessor operations between the two independent microprocessors. To take advantage of this feature, you must use an operating system that supports SMP, such as Microsoft® Windows NT® Server 4.0 (or later) or Novell® NetWare® 4.2 (or later).
note.gif (515 bytes) NOTE: If you decide to upgrade the system by installing a second microprocessor, you must order a microprocessor upgrade kit from Dell. Not all versions of the Pentium III microprocessor work properly as a second microprocessor. The upgrade kit from Dell contains the correct version of the microprocessor for use as a second microprocessor as well as instructions for performing the upgrade.  Both microprocessors must have the same part number and revision (or stepping) code, internal operating frequency, and cache size.
  • A minimum of 64 MB of system memory, upgradable to a maximum of 2 GB by installing combinations of 64-, 128-, 256-, or 512-MB registered SDRAM DIMMs in the four DIMM sockets on the system board.

    The registered, 72-bit-wide (168-pin) ECC SDRAM DIMMs installed in PowerEdge 2400 systems support ECC to check for and correct memory errors. ECC is performed by the memory controller in the RCC Server Set LE v3.0 system chip set. DIMMs do not need to be inserted in pairs.

  • A BIOS that resides in flash memory on the ISA bus that can be upgraded if required.

  • An optional, redundant power supply distribution board to accommodate up to two independent power supplies.

  • A single, 1.44-MB 3.5-inch diskette drive.

  • A 17/40X SCSI CD-ROM drive.

The system board includes the following features:

  • Five PCI slots and one PCI/ISA-shared expansion-card connector, located on the system board. PCI slots 1 through 4 are unshared, 64-bit, 33-MHz PCI slots; PCI slot 5 is a 64-bit, 33-MHz slot that is shared with ISA slot 5. Slot 6 provides a 32-bit, 33-MHz PCI slot for use with the optional Dell Remote Assistant Card (DRAC) or other PCI accessories.

  • A VGA-compatible video subsystem with an ATI RAGE IIC video controller. This video subsystem contains 4 MB of SDRAM video memory (nonupgradable). Maximum resolutions are 1024 x 768 x 256 colors (noninterlaced). In 800 x 600 and 640 x 480 resolutions, 16.7 million colors are available for true-color graphics.

  • An integrated National Semiconductor PC97317 super I/O controller that controls the bidirectional parallel port, two serial ports, keyboard, mouse, and the diskette drive in the externally accessible front bay. The super I/O controller resides on the ISA bus.

    The parallel port can be set to operate in the following modes via the Parallel Mode option in the System Setup program: output-only (AT-compatible), bidirectional (PS/2-compatible, or Extended Capabilities Port (ECP).

  • An integrated Intel 82559 10/100 NIC, which provides an Ethernet interface.

  • An optional integrated PowerEdge Expandable RAID Controller (PERC) 2/Si that supports RAID levels 0, 1, 5, and 10.

  • An integrated Adaptec AIC-7890 Ultra2/LVD SCSI host adapter that supports up to six 1-inch or four 1.6-inch internal SCSI hard-disk drives via a SCSI backplane board and special SCSI hard-disk drive carriers. The SCSI backplane automatically configures SCSI ID numbers and SCSI termination on individual hard-disk drives, greatly simplifying drive installation. 

  • An integrated Adaptec AIC-7880 Ultra/Wide SCSI secondary host adapter (implemented as Ultra/Narrow) provides connections for tape drives and CD-ROM drives via a 50-pin connector.

  • SCSI backplane options include a 1 x 4 and 1 x 6 hot-pluggable backplane. The hot-pluggable backplanes support hot-pluggable SCSI hard-disk drive installation and removal. The integrated SCSI controller resides on the PCI local bus for optimum performance.

  • Integrated server management circuitry that monitors operation of the system fans as well as critical system voltages and temperatures. The integrated server management circuitry works in conjunction with the optional HP OpenView Network Node Manager Special Edition (NNM SE) and the Dell Hardware Instrumentation Package (HIP) software package.

  • A PS/2-style keyboard port, dual USB ports, and a PS/2-compatible mouse port.

The PowerEdge 2400 system is available in a floor-standing or a rack configuration and can be changed from one configuration to the other via customer kits.

The following software is included in the system:

  • Video drivers for displaying many popular application programs in high-resolution modes. For more information on these drivers, see "Using the Dell OpenManage Server Assistant CD" in the User's Guide.

  • SCSI device drivers that allow the operating system to communicate with devices attached to the integrated SCSI subsystem. For more information on these drivers, see "Installing and Configuring SCSI Drivers" in the User's Guide.

  • The System Setup program for quickly viewing and changing the system configuration information.

  • The Resource Configuration Utility (RCU), which allows users to modify certain PCI configuration settings. RCU must run whenever ISA expansion cards are installed or removed to prevent hardware conflicts.

  • Enhanced security features, including a user password and a supervisor password, are available through either the System Setup program.

  • Diagnostics for evaluating the computer's components and devices. For information on using the system diagnostics, see "Using the Dell OpenManage Server Assistant CD" in the User's Guide or see "Running the Dell Diagnostics" in the Installation and Troubleshooting Guide.


Technical Specifications

Processor

Microprocessor type one or two Intel Pentium III microprocessors with an internal operating frequency of at least 500 MHz and an external operating frequency of 100 or 133 MHz
Internal cache 32-KB L1 cache; 256- or 512-KB L2 cache (512 KB L2 cache only in 100 MHz FSB processors)
Math coprocessor internal to microprocessor

Expansion Bus

Bus types PCI bus (operating at 33-MHz) and ISA bus (operating at 8.33 MHz)
Expansion slots five full-length 64-bit, PCI slots: PCI1 through PCI4;
PCI5 is a shared, full-length 32-bit PCI or 8- or 16-bit ISA slot. 
PCI6 is a 32-bit, 33-MHz PCI for use with the optional DRAC 2 card

Memory

DIMM sockets four 168-pin sockets
DIMM capacities 64-, 128-, 256-, or 512-MB registered SDRAM DIMMs; must be certified for 133-MHz operation
Minimum RAM 64 MB
Maximum RAM 2 GB (using 512-MB DIMMs)
External cache none

Drives

Diskette drive 3.5-inch, 1.44-MB diskette drive included with standard system
SCSI hard-disk drives formatted capacities from 9 GB to 36 GB
SCSI devices integrated Adaptec AIC-7890 Ultra2/LVD SCSI host adapter supporting four 1.6-inch SCSI hard-disk drives or six 1-inch SCSI hard-disk drives in internal bays;

integrated Adaptec AIC-7880 Ultra/Wide SCSI host adapter, implemented as Ultra/Narrow, supporting up to three SCSI devices in externally accessible front bays; 

a
n internal SCSI backplane, provides a physical connection, hot-plug capability, termination, and automatic configuration for the internal SCSI hard-disk drives
CD-ROM drive SCSI CD-ROM drive included with standard system

External Ports and Connectors

Serial   two 9-pin connectors
Parallel 25-pin connector (bidirectional)
Video 15-pin connector
PS/2-style keyboard six-pin mini-DIN connector
PS/2-compatible mouse six-pin mini-DIN connector
USB two USB-compliant 4-pin connectors
Ethernet RJ45 connector for connection to internal embedded NIC (Intel 82559 10/100 Ethernet controller)

Internal Ports and Connectors

Diskette drive 34-pin connector for internal 3.5-inch, 1.44-MB diskette drive
Ultra/Narrow SCSI controller 50-pin connector for internal SCSI CD-ROM drive or optional tape backup units
Ultra2/LVD SCSI controller 68-pin connector for internal SCSI drives
XSMB connector
(8-pin header connector)
reserved
Embedded 10/100 Ethernet controller connected to external RJ45 connector
Embedded PowerEdge RAID controller (optional) Intel i960® RM on system board providing PCI-to-PCI bridge;
two integrated SCSI channels residing on the secondary PCI bus;
optional software and unbuffered 64-MB SDRAM DIMM;
support for RAID levels 0, 1, 5, and 10

Video

Video type ATI RAGE IIC PCI video controller; VGA connector
Video memory 4-MB SDRAM standard
(not upgradable)

Power

Standard (nonredundant) DC power supply:
      Wattage 330 W
      Heat dissipation 600 BTU/hr (nominal)
      Input voltage 90 to 135 V at 47-63 Hz
180 to 265 V at 47-63 Hz
autoranging
      Output voltages
        and maximum
        current
+5 VDC at 35 A
+3.3 VDC at 18 A
+12 VDC at 14 A
–12 VDC at 0.3 A
–5 VDC at 0.3 A
+5 Vfp at 1.2 A
Optional hot-pluggable DC power supply (ratings are for each supply):
      Wattage 330 W
      Heat dissipation 600 BTU/hr (nominal)
      Input voltage 90 to 265 V at 47-63 Hz
autoranging
      Output voltages
        and maximum
        current
+5 VDC at 35 A
+3.3 VDC at 10 A
+12 VDC at 18 A
–12 VDC at 0.8 A
–5 VDC at 0.3 A
+5 Vfp at 1.2 A
Backup battery 3-V CR2032 lithium coin cell

Physical

Rack mount (6U):
      Height 26 cm (10.25 inches)
      Width 43.2 cm (17 inches)
      Depth 58.4 cm (23 inches)
Tower chassis:
      Height 43.9 cm (17.3 inches)
      Width 26.1 cm (10.3 inches)
      Depth 59.2 cm (23.3 inches)
Weight 31.75 kg (70.0 lb) maximum configuration

Environmental

Temperature:
      Operating 10°C to 35°C (50°F to 95°F)
      Storage –40°C to 65°C (–40°F to 149°F)
Relative humidity:
      Operating 8% to 80% (noncondensing)
      Storage 5% to 95% (noncondensing)
Maximum vibration:
      Operating 0.25 G (half-sine wave) at a sweep of 3 to 200 Hz for 15 minutes
      Storage 0.5 G at 3 to 200 Hz for 15 minutes
Maximum shock:
      Operating six consecutive shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) at 50 G for 2 milliseconds
      Storage six consecutive shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) at 92 G for 2 milliseconds
Altitude:
      Operating –16 to 3048 m (–50 to 10,000 ft)
      Storage –16 to 10,600 m (–50 to 35,000 ft)